Wash 20
Type set at wdth 64 by its own beam angle
Every figure on this page is read from HF-W20.ies — the photometric file this house already publishes for download. Nothing here is typed by hand.
Published as LM-63 because the head is built in North America. One house, two formats, and the page does not care which.
HF-W20.ies is read, and every figure on this page is already computed from it. The room is next.
The section, at C0–C180
From the file
| Format | LM-63-2002 |
|---|---|
| Photometry | Type C |
| V·angles | 91 |
| H·angles | 1 · axial |
| Resolution | 1.00° |
| Test | HF-GONIO-0120 |
| Opening | dia. 0.190 m |
| Downward flux | 100.0 % |
Reconciled at build
- Luminous flux
- declared13500 lmmeasured13400.0 lmΔ (tol. ±3 %)−0.74 %
- Beam angle, 50%
- declared20.0°measured20.0°Δ (tol. ±1.0°)0.00°
- Field angle, 10%
- declared38.0°measured37.6°Δ (tol. ±1.5°)−0.41°
The build refuses this page if any of those exceed the tolerance beside it. Run pnpm check:photometry to see it happen.
The file itself
Zonal lumens
Integrated from the file in ten-degree bands. They sum to 13400.0 lm, which is the same integral the reconciliation above compares against the catalogue.
Variants
| Order code | CCT | CRI | Finish |
|---|---|---|---|
| HF-W20/TU | 3200 K | 96 Ra | Open white — tungsten |
| HF-W20/DA | 5600 K | 94 Ra | Open white — daylight |
| HF-W20/CT | 4300 K | 92 Ra | Half CTB |
Housing finishes: Black. Housing depth 0.550 m.